Customer success stories Kruger makes its processes more energy-efficient
Project 1: Replacement of primary centrifugal cleaners in approach systems
The mill's centrifugal cleaners required very high pressure differentials to operate properly, which resulted in pressure drops of 345 kPa. To compensate, a primary mixture pump was used to supply the cleaners. The greater the pressure differential, the more pumping power required and, consequently, the greater the energy expenditure. Cleaners with a smaller diameter were installed, resulting in a reduction in pressure drops of about 160 kPa. The result is reduced energy consumption by the pumping system that supplies the three paper machines. Project 2: Replacement of level control valves on high-consistency pulpers A VFD was installed on the pumps so that the pumps, rather than the control valves, maintain pulper levels, thus reducing the pumping power required.
|
|||||||||||||||||||||||||||||||||||||||||||||